Chongqing SendOil Technology & Development Company, LTD.Contact hotline +86 23 6832 2848
SENDOILPETROLEUM TECHNOLOGY
SDZ3000-3 triple-panel LCD drilling instrumentationSENDOIL / Drilling instrumentation systems
Drilling instrumentation systems

SDZ3000-3 triple-panel LCD drilling instrumentation

When more parameters are to be displayed on the rig, the SDZ3000-3 rig parameters monitor is recommended. SDZ3000-3 uses a three-span LCD-based visible screen. In general, when the well team is required to display a full range of drilling parameters, it is possible to select a standard drilling parameter.

Product selection & technical support
Inquire about this product023-68322848
Overview & technical specifications

SDZ3000-3 triple-panel LCD drilling instrumentation

 When more parameters are to be displayed on the rig, the SDZ3000-3 rig parameters monitor is recommended. SDZ3000-3 uses a three-span LCD-based visible screen. In general, when the well team is required to display a full range of drilling parameters, it is possible to select a standard drilling parameter.

Main technical indicators:

1. Main measurement ranges and accuracy

Measurement parameters

Measurement range

Display accuracy

Record precision

Notes

 Big hooks.

 0 ~ 4200kN

 ±1.5%

 ±1.5%

 or User Selection

 Standpipe pressure

 0 ~ 40MPa

 ±2.5%

 ±1.5%

 Rotary table torque

 0 ~ 1000A

 ±2.5%

 ±1.5%

 Tong torque

 0 ~ 100kN

 ±2.5%

 ±1.5%

 Ride.

 Pump 1/2/3

 0 ~ 200SPM

 ±1.5%

 ±1.5%

 Rotary table speed

 0 ~ 300RPM

 ±1.5%

 ±1.5%

 Wellhead mud return

 0 ~ 100%

 ±1.5%

 ±1.5%

 Slurry pool fluid level

 0.25 ~ 5m

 ±1.5%

 ±1.5%

 Pool 1# ~ 8#

 Hook height

 0 ~ 50m

 ±1.5%

 ±1.5%

 H2S

 0 ~ 100ppm

 ±1%

 ±1.5%

 Concentration alert.

 Flammable gas

 0 ~ 100%LEL

 ±1%

 ±1.5%

 Concentration alert.

 Deep well.

 0 ~ 15000m

 ±1.5%

 ±1.5%

 Derivative parameters

 Drilling time

 0 ~ 720min/m

 ±1.5%

 ±1.5%

 Derivative parameters

 Cumulative pump

 0 ~ 999999Str

 ±1.5%

 ±1.5%

 Derivative parameters

 Mechanical drilling speed

 0 ~ 999m/hour

 ±1.5%

 ±1.5%

 Derivative parameters

2. System indicators

    DAQ simulation input: 16 channel

    DAQ digital input: 4 channel

    DAQ switch input: ≤4 channel

    Sampling accuracy: 1 second, 

    Show refresh rate: 1-3 seconds

    Error rate: DAQ to backstage station not more than 10-8

    Workstation communication distance: 200 m

    System blast marker: ExdibnRIIBT4

    Protection level: IP65 (outdoor instruments)

3. Instrument working environment

    Ambient temperature: Outdoor instruments – 25°C ~ 70°C, indoor instruments – 0°C ~ 40°C (no external heating panels required)

    Humidity: 85% RH

    Electricity: 220 VAC ± 20%, 50 Hz ± 10% or 110 VAC ± 20%, 60 Hz § 10%

    Drilling station uninterruptible power supply > 2 hours (UPS online)

LET’S WORK TOGETHER

Your requirements. The right products.

Timely, effective, professional and standardized service, around the clock.