SENDOIL / Drilling instrumentation systemsSDZ3000-3 triple-panel LCD drilling instrumentation
When more parameters are to be displayed on the rig, the SDZ3000-3 rig parameters monitor is recommended. SDZ3000-3 uses a three-span LCD-based visible screen. In general, when the well team is required to display a full range of drilling parameters, it is possible to select a standard drilling parameter.

When more parameters are to be displayed on the rig, the SDZ3000-3 rig parameters monitor is recommended. SDZ3000-3 uses a three-span LCD-based visible screen. In general, when the well team is required to display a full range of drilling parameters, it is possible to select a standard drilling parameter.
Main technical indicators:
1. Main measurement ranges and accuracy
|
Measurement parameters |
Measurement range |
Display accuracy |
Record precision |
Notes |
|
Big hooks. |
0 ~ 4200kN |
±1.5% |
±1.5% |
or User Selection |
|
Standpipe pressure |
0 ~ 40MPa |
±2.5% |
±1.5% |
|
|
Rotary table torque |
0 ~ 1000A |
±2.5% |
±1.5% |
|
|
Tong torque |
0 ~ 100kN |
±2.5% |
±1.5% |
Ride. |
|
Pump 1/2/3 |
0 ~ 200SPM |
±1.5% |
±1.5% |
|
|
Rotary table speed |
0 ~ 300RPM |
±1.5% |
±1.5% |
|
|
Wellhead mud return |
0 ~ 100% |
±1.5% |
±1.5% |
|
|
Slurry pool fluid level |
0.25 ~ 5m |
±1.5% |
±1.5% |
Pool 1# ~ 8# |
|
Hook height |
0 ~ 50m |
±1.5% |
±1.5% |
|
|
H2S |
0 ~ 100ppm |
±1% |
±1.5% |
Concentration alert. |
|
Flammable gas |
0 ~ 100%LEL |
±1% |
±1.5% |
Concentration alert. |
|
Deep well. |
0 ~ 15000m |
±1.5% |
±1.5% |
Derivative parameters |
|
Drilling time |
0 ~ 720min/m |
±1.5% |
±1.5% |
Derivative parameters |
|
Cumulative pump |
0 ~ 999999Str |
±1.5% |
±1.5% |
Derivative parameters |
|
Mechanical drilling speed |
0 ~ 999m/hour |
±1.5% |
±1.5% |
Derivative parameters |
2. System indicators
DAQ simulation input: 16 channel
DAQ digital input: 4 channel
DAQ switch input: ≤4 channel
Sampling accuracy: 1 second,
Show refresh rate: 1-3 seconds
Error rate: DAQ to backstage station not more than 10-8
Workstation communication distance: 200 m
System blast marker: ExdibnRIIBT4
Protection level: IP65 (outdoor instruments)
3. Instrument working environment
Ambient temperature: Outdoor instruments – 25°C ~ 70°C, indoor instruments – 0°C ~ 40°C (no external heating panels required)
Humidity: 85% RH
Electricity: 220 VAC ± 20%, 50 Hz ± 10% or 110 VAC ± 20%, 60 Hz § 10%
Drilling station uninterruptible power supply > 2 hours (UPS online)